Bird Fanciers Profile Panel III

Test Code: 401709P
Expand All Collapse All
Clinical Utility

For patients who have both precipitating antibody specific for bird antigens and the symptoms and the clinical findings for pneumonitis, a diagnosis of bird fancier's lung disease may be appropriate. It is important to recognize that a positive serology alone cannot be used to establish the diagnosis of HP or Bird Fancier's Lung without the appropriate clinical findings and exposure history. In patients who lack the symptoms of HP but who have precipitating antibody (usually IgG) the serology can be taken to document significant exposure to bird antigens. Although the gel diffusion methods may be less sensitive than new methods, such as the ELISA tests for these bird antigens, it may be more specific.

Procedure

ImmunoCAP® FEIA - IgE, Gel Diffusion (Ouchterlony)

3-5 business days from receipt of specimen

Specimen Type Order Code CPT Code NY Approved Volume Assay Range Special Instructions
serum 401709P (82785 x 1), (86003 x 5), (86331 x 12) No

2 mL

See Individual Test

  • 2 mL (minimum) collected in red-top or SST.
  • Separate serum from cells by centrifugation. .
  • Transfer serum to screw-cap tube for shipment. If specimen was collected in SST, the entire tube can be shipped following centrifugation.
  • Specimen may be shipped ambient or frozen.

Specimens are approved for testing in New York only when indicated in the Specimen Information field above.

The CPT codes provided are based on Viracor Eurofins' interpretation of the American Medical Association's Current Procedural Terminology (CPT) codes and are provided for general informational purposes only. CPT coding is the sole responsibility of the billing party. Questions regarding coding should be addressed to your local Medicare carrier. Viracor Eurofins assumes no responsibility for billing errors due to reliance on the CPT codes illustrated in this material.

Specimen Volume Requirements

Calculate specimen volume needed for total number of IgE/ImmunoCAP allergens ordered

Dead Volume: 300 µL
Each Allergen: 40 µL

Enter the number of tests and click the Calculate button.

For panels, please include total test count.

*This calculator is intended to help assess appropriate specimen volume for IgE/ImmunoCAP allergen tests. Viracor Eurofins is not responsible for miscalculations and encourages clients to refer to test specific specimen volume requirements listed within the test menu, or to contact client services at 800-305-5198 with any questions.